wire going to the inter-cell strap as on the
Monitor and also a red wire connecting to the
input strap on the adjacent cell on the side
opposite.There
is approximately 6vdc between the two wires.
Current drain when the acid level up is fine
and the LED is off, is very low.
The
flashing Blue LED provides an Alert to the operator
that next time around the battery should be
charged and then distilled water added. During
charging, the electrolyte heats up and expands,
therefore the water should be added afterwards
to prevent overfill.
Probe
length is 2-1/8"
|